Ge interlock kit

Ge interlock kit


Wondering if anyone can tell me if there is a ge interlock kit that would work on a ge 100 amp panel model tm3210ccu gold powermark. I see that lowes and home depot have one but they have different panels they are Model # THQLLX1 and ThQLLX4? Thanks for any help or suggestions.. I'm sure one of the pros can tell you off the top of their heads... But I'd also recommend you at least look into one of these: Generator InterLock Kit I just installed one and it was a piece of cake! Of course, if given the option, the OEM model is probably your best bet. The tm3210ccu 100 amp GE panel will not work with the one's sold at lowes and home depot They are made for 150 or 200 amp service with main being 4 pole breakers . Therefore the one they sell comes short and will not catch one of the breakers on 2 4. The tm32 is only 2 pole breakers and thats why the spaceing won't work.. Thanks for updating us with that information. some question about this I talked to a ge tech and he said it wouldn't work, but another said he thought it would will I just got one had order myself for my ge box tm3210ccu opened the package and found that it would work at least Im pretty sure it would took all mesurment and then held it up. So now I think I must recant my old post and say it looks like it will work.. If you move it just a slight down or up it will catch about 1/4 inch instead of 3/8s and still will prevent you from turning the dedicated 230 or what ever size you use on with the main off. so for 39 bucks it's worth a shot. I am assuming when you throw the main it work the same and prevent you from turning it on If you look at the configuration if it works one way should work the other.. and also instead putting a double throw in slots 24 goind to use the ge mini 30 amp double throw.. sorry if I'm confusing but it really should work alot cheaper then interlock,com 149 bucks for theres ge mini 30 amp double throw. GE breakers are tricky. Wait for the pros to comment. and also instead putting a double throw in slots 24 goind to use the ge mini 30 amp double throw I am just guessing here, but did you mean double pole? If you are using a double throw switch, that would be similar to a manual transfer switch. Hi Just to let you guys know the ge interlock kit for the 150 and 200 amp ge panels does work onthe 100 amp tm3210ccu I had bought one and looked like it would work well today I installed it and works. Did not use the guide they give I held it up and shiffed it very little not as far as the guide guide was at the end of where I drilled but if definetly works cheap way to go so good luck Yes: I just put one in today and does work mark it manualy and it works fine...








Related Posts:




  • Generator and interlock basic questions

    Generator and Interlock basic questions...Hey guys, I live in the area affected by Hurricane Sandy. As such, I have been running a borrowed generator for heat/basic lighting. I'll admit it is a ri...


  • Hardwire portable generator to load center via interlock kit and breaker

    hardwire portable generator to load center via interlock kit and breakerHello, Pardon the newbie question. I have purchased a 30 amp 7500w portable generator that I was going to connect to the hou...


  • Generator interlock kit on cutler hammer br panel

    Generator Interlock Kit on Cutler Hammer BR PanelHi - I think I Have a Cutler Hammer BR series panel (I need to look closer to be sure). I understand that some other brands sell replacement panel...


  • Generator interlock install

    Generator interlock installInterested in installing (or having installed) a generator interlock or transfer switch for my home. Main panel is 200A, Square D Homeline. I like the interlock setup as...


  • Doityourself rip fence for craftsman table saw

    Do-it-yourself rip fence for Craftsman table sawI am currently in the planning stages for creating a home woodshop when I return home from school in a few weeks. Last summer I purchsed a 10 crafts...